MechLab EN PL
Free beta until the end of 2026. Every file, STEP, DXF and the PDF report included, downloads for free right now. We are testing the layout and how the pages work, and collecting feedback on new tools. The calculations themselves are not experimental: every tool is checked against worked examples and independent calculations. See the calculation verification.

Welded joint calculator: butt and fillet welds

Pick the joint: a butt weld across a bar, fillet welds in shear, an angle bar welded with unequal welds, or a bracket welded to a wall (bending and shear). MechLab applies the weld strength factors z, deducts the craters and writes every step the way it is done in a machine design course.

Start from

Joint

Bar and butt weld

Material and load

Joint

Results

Export

Every file is free during the beta.

Free in beta PDF

Calculation report: inputs, formulas with your numbers, checks, sources.

If MechLab saved you time, you can buy me a coffee. It keeps the tools free.

Calculation sheet

Method, assumptions and limits

Allowable stresses in the weld

The weld is the weakest section of the joint, so the allowable stress of the parent metal is reduced by a weld strength factor:

weld strength factor
  • butt weld: in tension, in compression, in bending, in shear
  • fillet weld: for every load

A pulsating load takes , an alternating load .

Butt weld

The design throat is the thinner part, . With run-off plates the whole width counts, ; without them two craters are lost, . An inclined weld at angle to the force is long.

Fillet weld

By convention a fillet weld is checked in shear on its throat section:

throat, about rounded down to whole mm, mm and
load-bearing length, (two craters of ); a weld all around has no craters

Longitudinal welds should be to long and at least 40 mm.

Angle bar with two welds

The welds at the heel and at the toe are sized for equal stress. Moments about the line of the force through the centroid give:

distance of the centroid from the heel
leg width

Lengths are rounded up to 5 mm and is added for the craters. The bar is checked in tension, .

Bracket in bending

The force on the arm bends the weld group and shears it. The throat sections are rectangles in the wall plane:

section modulus of the weld group, for two vertical welds
throat area of the welds that carry the shear (the vertical ones when there are any)

Not covered

  • Eurocode 3 directional method and design resistances.
  • Fatigue by detail category and residual welding stresses.
  • Welds twisted by an in-plane moment, buckling of compressed bars.
Sources
  • Machine design (PKM) course material on welded joints: weld strength factors z, craters, butt and fillet weld formulas, worked examples 1–3.
  • EN 10056-1: dimensions and section properties of equal angles.
  • EN 10058: hot-rolled flat bars, standard widths.

More: Joints

How to calculate a welded joint

In a welded joint the weld is the weakest section, so its allowable stress is the parent metal allowable times a weld strength factor z. The calculation then depends on the weld type: a butt weld works like the bar it joins, a fillet weld is checked by convention in shear on its throat section a·l. The calculator follows the method taught in machine design (PKM) classes and writes out every step.

F = 35 kN l = 200 2 × a = 8, h = 275 weld throats
Bracket welded to a wall with two vertical fillet welds. The force on the arm bends the weld group and shears it at the same time.

Step by step

  1. Allowable stresses. kr = Re/xe, kt = 0.6·kr, and in the weld k′ = z·k: a butt weld takes z = 0.8 in tension, 1.0 in compression, 0.9 in bending, 0.65 in shear; a fillet weld 0.65 for every load. Lower k for pulsating (×0.6) or alternating (×0.375) loads.
  2. Weld size. A butt weld has a = g. A fillet weld has a ≈ 0.7·h, rounded down to whole millimetres, 2 to 15 mm and not more than 0.7 of the thinner part.
  3. Craters. A butt weld loses a at each end unless it runs out onto run-off plates (l = b − 2a). A fillet weld loses 1.5a at each end (l = lr − 3a). A weld all around has no craters.
  4. Stresses. σ = F/(a·l), τ = F/(a·l), σg = M/W. Combine them with Huber's formula: √(σ² + 3τ²).
  5. Unequal welds. For an angle bar the welds at the heel and the toe share the force in the ratio of their distances to the centroid line, so both have the same stress.

Worked example: bracket welded to a wall

A bracket of S235 steel is welded to a plate with two vertical fillet welds 275 mm high, throat a = 8 mm. A force F = 35 kN acts 200 mm from the wall. Static load, xe = 2.

StepFormula with numbersResult
Allowable in the weldkr = 235/2, kt = 0.6·kr, kt′ = 0.65·kt45.83 MPa
Load-bearing lengthl = 275 − 3·8251 mm
Weld group modulusW = 2·8·251²/6168003 mm³
Bendingσg = 35000·200/W41.67 MPa
Shearτ = 35000/(2·8·251)8.72 MPa
Combined stressσz = √(σg² + 3τ²)44.32 MPa ≤ 45.83

The weld holds with σz = 44.3 MPa against 45.8 MPa. The smallest throat that still works is a = 7.68 mm. For a butt weld on run-off plates in a 10 mm S235 bar carrying 165 kN, the same tool gives b ≥ 175.5 mm, so a flat bar 10 × 180.

Frequently asked questions

What is the weld strength factor z?

It reduces the allowable stress of the parent metal to the allowable stress of the weld: k′ = z·k. In the course tables a butt weld has 0.8 in tension, 1.0 in compression, 0.9 in bending and 0.65 in shear, and a fillet weld 0.65 for every load.

Why subtract 3a from a fillet weld?

The start and the end of a weld (the craters) are weak. Each crater of a fillet weld is taken as 1.5a long, so 3a in total does not carry load. A weld all around a part has no ends, so nothing is subtracted.

What are run-off plates?

Small plates welded at both ends of a butt weld so that the weld starts and ends on them. They are cut off afterwards, and the full width of the bar counts as weld length.

How do I take a pulsating or alternating load?

Pick it in the Load field. The allowable stresses drop to 0.6·k for a pulsating load (from zero to the maximum) and 0.375·k for an alternating load (tension and compression).

Is this the Eurocode method?

No. It is the allowable stress method used in machine design (PKM) classes. Steel structures designed to EN 1993-1-8 use the directional or simplified method with design resistances instead.

Something wrong or missing? Tell us and it gets checked and fixed. It takes a minute.